UPSP

Uninterrupted Power System

Protection against harmonic distortions, power surges, peaks, under and overvoltage, noise and transients in the line and blackouts.

Protection through UPS is critical for telecommunications infrastructures, medical areas, sub-stations, off shore and naval.

Meets the main technical specifications, norms and world standards.

Optional redundant configuration.

A complete remote monitoring solution through electronic modules, with remote alarms, via dry contact, which inform system status, alarms, autonomy levels, protections, etc.

It also has interfaces with communication protocols.

It can be supplied in several formats depending on the customer's need, which can be:

Single-phase input - Single-phase output
Three-phase input - Single-phase output
Single-phase input - Three-phase output
Three-phase input - Three-phase output

Quero este produto

Preencha os campos abaixo para entrar em contato conosco:

Single-phase voltage Ø1110Vac, 127Vac, 220Vac, 230Vac
Three-phase voltage Ø3220Vac, 380Vac, 440Vac, 460Vac, 480Vac, 690Vac
Tolerance:± 15%
24Vdc1 to 3kVA
48Vdc1 to 5kVA
110Vdc / 125Vdc1 to 40kVA
220Vdc / 250Vdc1 to 60kVA
360Vdc / 480Vdc1 to 100kVA
Single-phase voltage Ø1110Vac, 127Vac, 220Vac, 230Vac
Three-phase voltage Ø3220Vac, 380Vac, 440Vac, 460Vac, 480Vac, 690Vac
Power1 to 100kVA (Other powers on request)
Income> 85%
Frequency50Hz, 60Hz or 400Hz
CommunicationModbus RS-485 / Ethernet TCP-IP
HMI Available infomationVoltages and Input Current, Output and DC Link, Temperature and Frequency, Data Logger
Filter:EMI / RFI
RectifierThyristorized 6 or 12 pulses, or SMPS
InverterIGBT or Mosfet
BatteriesSupply of batteries and shelf according to the required autonomy of the system, and it may be Acid Lead or Alkaline
VDC Consumer OutputOutput for power of VDC consumers (Protections, flow computers, among others), using the same equipment and battery bank to power critical AC and DC loads.
Automatic Transfer Static KeyAutomatic transfer static key, with synchronized transfer time < 3ms, or non-synchronized <16ms.
Manual Transfer KeyManual key for transfer between inverter output and Alternative Network, for maintenance.
CommunicationPossibility of other communication protocols such as DNP3, IEC 61850 and SNMP via Converter.
Input IsolationCan be supplied with Isolation Transformer and/or Stabilizer for Alternative Input