Uninterrupted Power System
Protection against harmonic distortions, power surges, peaks, under and overvoltage, noise and transients in the line and blackouts.
Protection through UPS is critical for telecommunications infrastructures, medical areas, sub-stations, off shore and naval.
Meets the main technical specifications, norms and world standards.
Optional redundant configuration.
A complete remote monitoring solution through electronic modules, with remote alarms, via dry contact, which inform system status, alarms, autonomy levels, protections, etc.
It also has interfaces with communication protocols.
It can be supplied in several formats depending on the customer's need, which can be:
Single-phase input - Single-phase output
Three-phase input - Single-phase output
Single-phase input - Three-phase output
Three-phase input - Three-phase output
Preencha os campos abaixo para entrar em contato conosco:
Informe os seus dados para acessar os arquivos:
Single-phase voltage Ø1 | 110Vac, 127Vac, 220Vac, 230Vac |
Three-phase voltage Ø3 | 220Vac, 380Vac, 440Vac, 460Vac, 480Vac, 690Vac |
Tolerance: | ± 15% |
24Vdc | 1 to 3kVA |
48Vdc | 1 to 5kVA |
110Vdc / 125Vdc | 1 to 40kVA |
220Vdc / 250Vdc | 1 to 60kVA |
360Vdc / 480Vdc | 1 to 100kVA |
Single-phase voltage Ø1 | 110Vac, 127Vac, 220Vac, 230Vac |
Three-phase voltage Ø3 | 220Vac, 380Vac, 440Vac, 460Vac, 480Vac, 690Vac |
Power | 1 to 100kVA (Other powers on request) |
Income | > 85% |
Frequency | 50Hz, 60Hz or 400Hz |
Communication | Modbus RS-485 / Ethernet TCP-IP |
HMI Available infomation | Voltages and Input Current, Output and DC Link, Temperature and Frequency, Data Logger |
Filter: | EMI / RFI |
Rectifier | Thyristorized 6 or 12 pulses, or SMPS |
Inverter | IGBT or Mosfet |
Batteries | Supply of batteries and shelf according to the required autonomy of the system, and it may be Acid Lead or Alkaline |
VDC Consumer Output | Output for power of VDC consumers (Protections, flow computers, among others), using the same equipment and battery bank to power critical AC and DC loads. |
Automatic Transfer Static Key | Automatic transfer static key, with synchronized transfer time < 3ms, or non-synchronized <16ms. |
Manual Transfer Key | Manual key for transfer between inverter output and Alternative Network, for maintenance. |
Communication | Possibility of other communication protocols such as DNP3, IEC 61850 and SNMP via Converter. |
Input Isolation | Can be supplied with Isolation Transformer and/or Stabilizer for Alternative Input |