RCMP Plus

Excellent performance in the most varied applications!

They provide direct current power by possessing devices that ensure adequate voltage for consumers regardless of the battery charge cycle.

They are suitable for charging alkaline or acidic batteries, ventilated or regulated by valve (VRLA), ensuring prolonged service life due to the intelligent charging system, monitoring the batteries and providing the exact charge cycle for each type of battery.

Supplied in robust thyristor modules.

Suitable for places with high level of pollution and temperature, for its robustness and insulation.

Equipment of easy operation, installation and maintenance.

Quero este produto

Preencha os campos abaixo para entrar em contato conosco:

Single-phase voltage Ø1110Vac, 127Vac, 220Vac, 230Vac
Three-phase voltage Ø3220Vac, 380Vac, 440Vac, 460Vac, 480Vac, 690Vac
Limits±15%
Power factor0,67 to 0,92
Efficiency>80%
Voltage24Vdc / 48Vdc / 110Vdc / 125Vdc / 220Vdc / 250Vdc / 360Vdc / 480Vdc / 500Vdc / 600Vdc
Power1 to 25000A
CommunicationModbus RS-485 Possibility of other communication protocols such as ethernet TCP-IP, DNP3, IEC 61850 e SNMP via converter.
Available Information DisplayInput, output and battery voltages and current, temperature, frequency, operation, alarm and data logger
FilterEMI / RFI
RectifierThyristorized 6 or 12 pulses
Power SystemThe rectifier/charger can be supplied with a complete power system, composed of the rectifier charger, battery bank, panel with the electrical connections of the batteries, distribution panels among others.
Disconnection of batteriesDisconnection of consumers when the Vpe voltage of the batteries is at the minimum informed by the manufacturer
Drop Diode UnitConsumer voltage control for overvoltage protection
Remote AlarmsRemote alarms via relay parameterized according to the need of the project, with the possibility of up to 24 outputs.
Digital Inputs4 Digital Inputs for Control: Power Off / External Lock / Equalization Lock / Alarm Reset
Analog OutputsAnalog outputs 4-20mA, with the possibility of up to 10 parameterizable outputs for voltage and current, AC or DC
BatteriesBattery reading module, with measurement of Temperature, Symmetry, voltage and total current of the bank or each element. Test of the battery bank by the Rectifier.
Data loggerMemorization of up to 10,000 events, separated year, month, day, hour, minute, seconds
Power Factor CorrectionRectifier Power Factor Correction Circuit for >0.92
THD FixTHD Correction Circuit for IEE STD 519 Service
Cadastre seu e-mail abaixo e receba nossos conteúdos
Virtual store
Acesse nossa loja do Mercado Livre e adquira nossos produtos seriados.