Excellent performance in the most varied applications!
They provide direct current power by possessing devices that ensure adequate voltage for consumers regardless of the battery charge cycle.
They are suitable for charging alkaline or acidic batteries, ventilated or regulated by valve (VRLA), ensuring prolonged service life due to the intelligent charging system, monitoring the batteries and providing the exact charge cycle for each type of battery.
Supplied in robust thyristor modules.
Suitable for places with high level of pollution and temperature, for its robustness and insulation.
Equipment of easy operation, installation and maintenance.
Preencha os campos abaixo para entrar em contato conosco:
Informe os seus dados para acessar os arquivos:
Single-phase voltage Ø1 | 110Vac, 127Vac, 220Vac, 230Vac |
Three-phase voltage Ø3 | 220Vac, 380Vac, 440Vac, 460Vac, 480Vac, 690Vac |
Limits | ±15% |
Power factor | 0,67 to 0,92 |
Efficiency | >80% |
Voltage | 24Vdc / 48Vdc / 110Vdc / 125Vdc / 220Vdc / 250Vdc / 360Vdc / 480Vdc / 500Vdc / 600Vdc |
Power | 1 to 25000A |
Communication | Modbus RS-485 Possibility of other communication protocols such as ethernet TCP-IP, DNP3, IEC 61850 e SNMP via converter. |
Available Information Display | Input, output and battery voltages and current, temperature, frequency, operation, alarm and data logger |
Filter | EMI / RFI |
Rectifier | Thyristorized 6 or 12 pulses |
Power System | The rectifier/charger can be supplied with a complete power system, composed of the rectifier charger, battery bank, panel with the electrical connections of the batteries, distribution panels among others. |
Disconnection of batteries | Disconnection of consumers when the Vpe voltage of the batteries is at the minimum informed by the manufacturer |
Drop Diode Unit | Consumer voltage control for overvoltage protection |
Remote Alarms | Remote alarms via relay parameterized according to the need of the project, with the possibility of up to 24 outputs. |
Digital Inputs | 4 Digital Inputs for Control: Power Off / External Lock / Equalization Lock / Alarm Reset |
Analog Outputs | Analog outputs 4-20mA, with the possibility of up to 10 parameterizable outputs for voltage and current, AC or DC |
Batteries | Battery reading module, with measurement of Temperature, Symmetry, voltage and total current of the bank or each element. Test of the battery bank by the Rectifier. |
Data logger | Memorization of up to 10,000 events, separated year, month, day, hour, minute, seconds |
Power Factor Correction | Rectifier Power Factor Correction Circuit for >0.92 |
THD Fix | THD Correction Circuit for IEE STD 519 Service |