10 to 800CV
220V and 380V~440V
High Performance Vector
CLP Functions.
Motors: asynchronous and synchronous induction of permanent magnet.
Aplications
- Metallurgical
- Petroleum
- Chemistry
- Textile
- Construction
- Laboratory
- Food
- Paper
- Plastic
- Winch
- Laundry
- Sanitation
- Effluent
- Etc.
- Machinery industry: confection, compressors, extrusion, injection, braid, fans, blowing machine, blow molding, film blowing, cutting, conveyor belt, pumps, crusher, grinder, glass, polishing, laundry, drying machine, elevators, grinders, centrifues, etc.
Highlights
- 32-bit DSP-based control performs the high-speed and high-performance vector control algorithm.
- Operates with asynchronous induction motors or permanent magnet synchronous motors.
- Control mode: Vector control w/ PG (VC), vector control without feedback (SVC), Control V/F.
- Up to 7 speed control steps and 8 acceleration control steps can be performed.
- Basic PLC functions: up to 15 speed control segments and 8 acceleration control segments can be performed.
- You can add PID to regulate the braking system with DC.
- Restart with tracked speed for recovery after momentary loss of energy.
- Parameter to reduce energy consumption.
- Optional card for special applications.
- Overload capacity: current of 150% for 60s (SCV), 180% of rated current for 10s (VC).
- High-performance internal PID function of closed-loop control.
- 8 programmable control posts.
- Hot Pluggable keypad: can restore or copy 4 parameter groups of operation programs.
Quero este produto
Preencha os campos abaixo para entrar em contato conosco:
Catálogos para download
Informe os seus dados para acessar os arquivos:
Control System | High-performance vector control inverter based on 32-bit DSP |
Control Method | Control V/F, Vector Control W/O PG, Vector Control W/PG |
Auto torque boost function | Notices low frequency (1Hz) and controls in wide torque range in V/F control mode |
Control acceleration and deceleration | Direct mode and curve mode S. Availability of 4 options, 0 to 6500 seconds |
V/F curve mode | Linear, square root/ m-th power, custom V/F curve |
Overload capacity | Type G: rated current 150% -1 minute, rated current 180% -2 seconds. Type F: rated current 120% -1 minute, rated current 150% -2 seconds |
Maximum frequency | Vector control: 0 to 300Hz . V/F control: 0 to 3200Hz |
Carrier frequency | 0.5 to 16kHz: automatic frequency carrier adjustment according to load characteristics |
Input frequency resolution | Digital adjustment: 0.01Hz analog adjustment: maximum frequency x 0.1% |
Torque starting | Type G: 0.5Hz / 150% (vector control W/O PG). Type F: 0.5Hz / 100% (Vector Control W/O PG) |
Speed Range | 1:100 (Vector Control W/O PG) 1:1000 (W/PG vector control) |
Torque response | < 40ms (Vector Control W/O PG) |
Various | Torque boost, DC braking, jogging control, multi-speed operation, internal PID, automatic voltage control (AVR), torque control and limit |
Customization | Self checking of peripherals after energization, bus function (DC link) common, fast current limit, timing control |
Control input signals | Operation method, frequency parameter, start signal, multi-speed, emergency stop, wobbulate operation, reset failure, PID feedback signal |
Operation functions | Limited frequency, jump frequency, slip compensation, auto tuning, PID control, braking current control, reversal protection |
Protection | Overvoltage protection, undervoltage, over current, overload, overtemperature, overcurrent stall, over voltage lock, phase loss (optional), communication error, PID feedback signal abnormality, PG fault and short circuit protection to ground, IGBT temperature, on display, inverter fan control, operation re-establishment after a momentary power failure, acceleration control method at start-up , parameter protection function |
Input voltage (VAC phases) | 3Ø 380V (-15%) to 440V (+10%) |
Network frequency | 50/60Hz ± 5% |
Output voltage | 0-100% of network voltage |
Ramp time | 0,0 to 6.500 seconds |
Start/off, reset, logical turning direction | 8 (above 11kW). NPN or PNP |
Voltage level | 9 to 30Vcc 2,4k Ώ |
Analog input number | 3 |
Voltage level | 0 to 10Vdc |
Current level | 0 to 20 mA |
Quantity | 1 |
Voltage level | 24Vdc |
Precision pulse input | 0 to 100kHz |
Output number | 2 |
Analog output number | 2 |
Voltage level | 0 to 10Vdc |
Current level | 0 to 20 mA |
Quantity | 1 |
Precision pulse output | 0 to 100kHz |
Quantity | 2 |
Port | Communication port RS485/232 |
-10°C to 40°C | (temperature 40°C to 50°C, use reducing coefficient of 2% for each °C above 40°C) |
Security norms | IEC61800-5-1:2007 |
CEM norms | IEC61800-3:2005 |