5 to 30CV
220V / 380V~440V / 480V
Highlights
- Low power
- Compact
- Simple speed regulation
- Wall and DIN rais installation
- Higher rated current desing
- Higher overload current
- Shorter acceleration time
Aplications
- Textile
- Paper making
- Wires
- Packing
- Foods
- Fan
- Water pump
- Small vending machines
Quero este produto
Preencha os campos abaixo para entrar em contato conosco:
Catálogos para download
Informe os seus dados para acessar os arquivos:
Rated voltage | AC 1Ø 220V(-15%)~240V(+10%) / AC 3Ø 220V(-15%)~240V(+10%) AC 3Ø 380V(-15%)~440V(+10%) / AC 3Ø 480V(-10%)~480V(+10%) |
Frequency input | 50Hz/60Hz |
Control system | DSP based high performance vector control inverter |
Control method | V/F control, W/O PG control vector |
Automatic torque increase | Realizes low frequency (1 Hz) and self control of output torque in V/F mode |
Acceleration and Deceleration Control | Direct or S-curve mode, 4x available time range is 0.0 to 6500.0 s |
V/F curve mode | Linear, square root/m-th power, standard V/F curve |
Overload capacity | Type G: rated current 150% - 1 minute, rated current 180% - 2 seconds Type F: rated current 120% - 1 minute, rated current 150% - 2 seconds |
Maximum Frequency | 1- Vector control: 0 to 300hz; 2- V/F Control: 0 to 3200Hz |
Carrier frequency | 0.5 to 16 kHz, automatically adjusts the frequency according to the load |
Torque increase | Automatic torque boost, manual torque boost (0.1% to 30.0%) |
DC braking | DC braking frequency: 0.0 Hz to max. frequency, braking time: 0.0 to 100.0 seconds, braking current value: 0.0% to 100% |
Race control | Jog frequency range: 0.00 Hz to max. frequency; AC jog/deceleration time: 0.0 to 6500.0s |
Built-in PID | Easy-to-perform closed-loop control system for process control |
Automatic voltage regulation | Maintains a constant output voltage when mains voltage changes |
Self-inspection of peripherals after power on | After turning on the peripheral equipment, it will carry out safety tests, such as grounding, short circuit, etc. |
Common DC bus | Multiple inverter can use a common DC link; |
Fast current limiting | The current limiting algorithm is used to reduce the likelihood of inverter overcurrent and improve the unit's interference-free capability. |
Time control | Time control function: time setting range (0 min to 6500 min) |
DI1 input terminal | 6 digital input terminals, DI5 can be high speed pulse input (ψ2 0~100kHz) |
Analog Input AI1 | 1 AI1 analog input terminal, can choose 0~10v or 0~20mA input |
Multi-speed | Maximum 16 set speeds (using multi-function terminal or program) |
Emergency stop | Interrupt controller output |
Fault reset | When the protection function is active, it can automatically/manually reset the condition |
PID Feedback Signal | Including DC (0 to 10V) DC (0 to 20mA) |
Output terminal | 1 SPA collector output terminal, 1 relay output terminal, 1 DA1 analog output terminal |
SPA relay output | Each port has 40 signals which can be optional, relay contact capability, normally open contact 5A/AC 250V, 1A/DC 30V |
Frequency | 1 analog output, 16 signals can be selected such as frequency, current, voltage and others, output signal range (0 to 10V / 0 to 20mA) |
Command execution channel | 3 channels: operation panel, control terminals and serial communication port. They can be exchanged in many ways. |
Operation function | Threshold frequency, jump frequency, frequency offset, auto-tuning, PID control |
Frequency source | Total of 8 frequency sources: digital, analog voltage, multispeed and serial port. They can be exchanged in many ways. |
Inverter protection | Overvoltage protection, undervoltage protection, overcurrent protection, overload protection, overheat protection, overcurrent protection, overvoltage protection, phase loss protection (optional), external fault, communication error, PID feedback signal abnormalities , PG fault and ground short circuit protection. |
Operation information | Monitoring objects: operating frequency, set frequency, bus voltage, output voltage, output current, output power, output torque, status input terminal status, output terminal status, analog AI1 value, actual motor operating speed, PID set value percentage, PID feedback value. |
Error information | It saves a maximum of three error messages, the time, type, voltage, current, frequency and working status can be requested when the fault occurs. |
Key lock and selection | Lock part/all keys, define key function scope to prevent misuse |
IGBT temperature | Displays the current temperature of the IGBT |
RS485 | Built-in RS485 |
Storage temperature | -20~65°C |
Ambient humidity | Less than 90% RH, non-condensing |
Vibration | Below 5.9m/s² (=0.6g) |
Application sites | Indoor where there is no sunlight or corrosion, explosive gas and water vapor, dust, flammable gas, oil or salt, etc. |
Altitude | No derating below 1000m, 1% derating every 100m up to 3000m |
Protection level | IP20 |
Adopt safety standards | IEC61800-5-1:2007 |
Adopts EMC standards | IEC61800-3:2004 |
Cooling method | Forced air cooling |